  • Wiring channels are cut on the back of the distribution box

    Wiring channels are cut on the back of the distribution box

    What Is a Distribution Box?A distribution box, also known as a power distribution unit, is a critical component in any electrical system. It is the control center fo.


  • Should the cable be run in a cable tray or a cable duct

    Should the cable be run in a cable tray or a cable duct

    With a cable duct, you have to remove the cover to get inside. It's not ideal if you need to access cables often. If you're working on an electrical project, you've likely asked yourself this: Should I use a cable duct or a cable tray? It's a common question. Each system has unique characteristics that make it more suitable for specific applications. It indicates the direction in which the wires will follow from one side of a building to the other. From. Choosing between open cable tray and enclosed wireway/duct affects heat dissipation, ampacity derating, code compliance, and long-term maintenance.


  • Outdoor server rack air duct heat dissipation principle

    Outdoor server rack air duct heat dissipation principle

    At the heart of server rack cooling is a basic principle: heat moves from hot to cold. This process, called thermal transfer, is how your equipment gets rid of excess heat. Rack mount equipment generates heat as a result of the processes it completes; the amount of heat a piece of equipment dissipates is approximately equal to the total electrical power delivered to it. This heat is absorbed by the ambient air in the server, and removed by airflows generated by fans. Because data centers are high-density enclosed spaces that generate a significant amount of heat, traditional comfort cooling systems can't remove enough heat to protect the critical equipment. Additionally, well-managed heat control helps systems consume less power. IT system energy efficiency. Whether you're operating industrial automation systems with electrical switchgear or high-density data servers in server racks, effective temperature management is crucial for long-term performance and equipment longevity.

    [PDF Version]
  • Multiple fiber optic cables cut in Egypt

    Multiple fiber optic cables cut in Egypt

    Multiple subsea fiber optic cables in the Red Sea suffered simultaneous cuts on September 6, 2025, disrupting global internet and communications traffic. The incident began at 05:45 UTC and has forced operators to reroute traffic between Asia, the Middle East, and Europe over alternate paths. There has been concern about the cables being targeted in a Red Sea campaign by Yemen's Houthi rebels, which the. The severing of the SEA-ME-WE 4, IMEWE, and FALCON GCX subsea cables near Saudi Arabia has caused Internet issues in the Middle East and South Asia. 7 million kilometres of global data and internet cables. Each year, up to 200 submarine cable cut incidents reported, as per ICPC. The initial news seems to have originated from a Microsoft announcement published on Sunday.


  • How to cut a geogrid cable tray

    How to cut a geogrid cable tray

    The bends, tees, crosses, risers and reducers of wire mesh cable tray can be easily and quickly made live at the project by using a bolt cutter. Since the jaws of the bolt cutter drags a layer of zinc across the cut end and forms a protective layer. This lightweight power tool features a 330 ̊ swivel cutting head to make uts from any angle. Remember to. Developed by Interstates, this cable tray cutting guide acts as a guide for a metal cutting circular saw for cutting the side rail of a cable tray as well as a guide for drilling the connecting holes in the cable tray. During forklift offloading on uneven ground, one must exercise extreme caution to prevent load shifting. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned in this technical guide only apply to our own cable management ranges and cannot under any circumstances be transpos the enclosure.

    [PDF Version]
  • How to cut cable trays in Grenada

    How to cut cable trays in Grenada

    Direct mounting for the cable trays, trunking to the ground should be avoided, 50 mm clearance or spacing to be maintain over the floor. Cable tray cutting will be made using a hand held hack saw or jigsaw machine. It is important to get a square cut to ensure a good splice. In the Oglaend System Cutting Guideline you can easily find out what the optimal cutting lengths/intervals are for all modular products. Following the advice given. However, every installation is unique, and sometimes it becomes necessary to cut a cable tray to fit specific spaces or to connect different sections. Measuring and marking: Accurate measurement and marking techniques for cable trays. The method gives details of how the work will be carried out and what health and safety issues and controls that. cable trays are equivalent. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned in this technical guide only apply to our own cable management ranges and cannot under any circumstances be transposed to si osure, overheating or.

    [PDF Version]
  • How to cut the sheath of a fiber optic cable

    How to cut the sheath of a fiber optic cable

    Fiber Optic Strippers: These tools are specifically designed to remove outer jackets and buffer coatings without harming the core fibers. Must be operated with care to avoid crushing. How should optical fiber stripper be used? There are only three steps: First, strip the outer sheath of the optical fiber with optical fiber strippers; remove the stripped outer sheath of the optical fiber; and finally, cut the exposed aramid fiber with cable-cutting scissors. Heavy Duty Kevlar Scissors can be used to cut. The Jonard JIC-4366 cable sheath stripper and ring tool is ideal for copper cables, tight buffer optical fiber cables, and for slitting figure 8 or webbed cables. The tool is designed with two unique blades, the one located at the tip of the tool is for stripping and slitting cable, and the blade. In this week's video, Ben Hamlitsch shows you how to cut, strip, clean, and cleave your fiber optic cable! He also shares some best practices to follow and additional details you'll want to know along the way! Interested in learning more? Check out our detailed blog that covers this pro. Standard wire cutters or pliers can severely damage the delicate internal fibers.

    [PDF Version]
  • All power to the suspended platform s electrical distribution box is cut off

    All power to the suspended platform s electrical distribution box is cut off

    Power failure: The power supply to the platform may be interrupted. Check the power supply and. Suspended platforms, commonly referred to as swing stages, are essential tools for your work at heights, particularly when traditional scaffolds are not viable. As a worker, your safety is paramount when performing suspended work, and these platforms provide necessary access to structures such as. When there is a sudden power outage during construction, the power switch of the electric box should be cut off immediately to prevent accidents during power transmission. If you need. Suspended scaffolds are temporary work platforms that hang from secure anchorage points and are commonly used for exterior building work and maintenance tasks, such as window washing on high-rise buildings. These systems allow workers to reach elevated areas that are difficult to access with. Ensure suspended platform safety with guidelines on inspection, operator training, fall protection, load limits, and emergency procedures for safe high-rise work. They provide a safe and efficient way to access elevated areas.

    [PDF Version]
  • Cut the 90° bend in the cable tray

    Cut the 90° bend in the cable tray

    Creating a 90-degree elbow in an electrical cable tray, often called a "fabricated" or "mitered" bend, involves cutting, bending, and fastening a straight section of tray. The most common method involves creating two 45-degree cuts to form a 90-degree angle. Engineers and contractors in North America and. the cable tray is 3 metres in length, this doesnt matter but i think the width does. but the length of the part in the centre is the concern as i have seen different. The first step is to mark out the tray (A). Construction of a flat 90° bend (A) The amount of tray lip to be removed is equal to 2, 3/4 the width of the tray, half of this measurement will be removed on either side of the centre line. Perfect for electricians! #electrician #worklife Keywords: cutting cable tray techniques, 90 degree cable tray bend, cable tray installation tips, electrical work cable tray, bending cable trays, cable tray.